All Documents
Application notes, tech tips, and other documents related to the LI-7000.
| Summary | ||
|---|---|---|
| Measuring pCO2 and Dissolved Inorganic Carbonates in Water | Application note that describes how to use LI-COR analyzers in systems that measure the partial pressure of CO2 (pCO2) and dissolved organic carbonates in water. | application note |
| Measuring Small Volumes of CO2 with the LI-7000 | Application note about small volume CO2 measurements with the LI-7000. | application note |
| Communicating with LI-COR instruments using LabVIEW | Basic instructions that describe how to communicate with LI-COR instruments using LabVIEW. Includes sample programs to read data. | application note |
| The Importance of Water Vapor Measurements and Corrections | This application note describes how water vapor influences the measurement of carbon dioxide by infrared gas analysis in several ways, which can lead to significant measurement errors. | application note |
| Using CO2 and H2O Scrubbers with LI-COR Gas Analyzers | This application note describes the use of various chemicals used internally with LI-COR gas analyzers to keep absorbing gases out of internal spaces that are part of the optical path. | application note |
| Mylar Insulator Installation Kit | Installation Guide for the 7000-904 Mylar Insulator Kit. Insulates the keypad of the LI-7000. | install guide |
| Digital Board Upgrade Kit | Installation instructions for the 7000-902-1 Digital Board Upgrade Kit. | install guide |
| LI-7000 CO2/H2O Analyzer Instruction Manual | Instruction manual for the LI-7000 | manual |
| Air Pumps and Accessories for LI-COR Gas Analyzers | Suggested parts and vendors for air pumps and other accessories needed to flush the sample cells of many LI-COR closed-path gas analyzers. | tech tip |
| Using the Sable Systems DG-4 to set the H2O span for LI-COR gas analyzers | You can adjust the H2O span in many LI-COR gas analyzers with a dewpoint generated by the Sable Systems DG-4 Dewpoint Generator. This tech tip provides some details. | tech tip |
| USB Connection Issue on Windows 8 | This technical tip describes how to fix a problem whereby the USB port does not function with the LI-7000 on computers using Windows 8. | tech tip |
| Effects of temperature and pressure on CO2 infrared absorption with special emphasis on problems resulting from operation at high flow rates | Article describing the effects of temperature and pressure on absorption of infrared energy by carbon dioxide. | technical note |
| Effects of Temperature, Pressure, and Water Vapor on Gas Phase Infrared Absorption by CO2 | Article that describes the effects of temperature, pressure, and water vapor on absorption of infrared energy by carbon dioxide. | technical note |